<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-13 13-27-10
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 4/5, 47 dBuV Classic
Pilot RDS Phase Difference
6.9 kHz 84 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 41 kHz 6612 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,5 dBr 2,30 dBr 3,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Sonaatti A-Duuri (Boccherini) "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 41 kHz MIN: 10 kHz % above 76 kHz: 0,0000 Acquired: 2025/12/13 13.26.05 Total samples: 6612 Equivalent time: 0:05:30 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150
FM Scope MAX: 3,7 dBr MIN: 0,5 dBr AVE: 2,30 dBr % above 12,2 dBr: 0,0 Last value: 3,1 dBr (2025/12/13 13.26.04) 13.12 13.14 13.16 13.18 13.20 13.22 13.24 13.26 -1 0 1 2 3 4 Pm [dBr]